SEER2 and HSPF2 are rated at one point, not the whole range
SEER2 measures cooling efficiency and HSPF2 measures heating efficiency, both under lab conditions at set temperatures. A heat pump works harder in the deep cold or the worst humidity than the rating reflects. The number is useful for comparing one system against another, not for predicting exactly how it performs on the hardest day of the year.